HF-Ri TD 2 28/35/49/54 TL5 E+ 195-240V 913700695866 Dali Dimmable
Got a question about this product? Get in Touch
Having trouble finding what you're looking for?
We can source most electrical products.
Contact us, we're here to help.
Got a question about this product? Get in Touch
Having trouble finding what you're looking for?
We can source most electrical products.
Contact us, we're here to help.
| Remarks |
UK importer address: Signify Commercial UK Limited, 3, Guildford Business Park, GU2 8XG
|
| Application code |
E+
|
| Type version |
mk2
|
| Lamp type |
TL5
|
| Number of lamps |
2 piece/unit
|
| Number of products on MCB (16 A type B) (nom.) |
18
|
| Automatic restart |
Yes
|
| Input Voltage |
195-240 V
|
| Input frequency |
50 to 60 Hz
|
| Operating frequency (max.) |
110 kHz
|
| Operating frequency (min.) |
45 kHz
|
| Ignition method |
Warm Start
|
| Crest factor (max.) |
1.7
|
| Power factor 100% load (nom.) |
0.95
|
| Ignition time (max.) |
1 s
|
| Mains voltage performance (AC) |
-8%-+6%
|
| Mains voltage safety (AC) |
-10%-+10%
|
| Earth leakage current (max.) |
0.5 mA
|
| Inrush current width |
0.25 ms
|
| Standby power consumption (max.) |
0.25 W
|
| Ballast factor (nom.) |
1
|
| Power losses (nom.) |
7.2 W
|
| Inrush current peak (max.) |
28 A
|
| Connector type input terminals |
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
|
| Cable capacity output wires mutual (max.) |
200 pF
|
| Connector type output terminals |
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
|
| Connector type control input terminals |
WAGO 251 universal connector [ Suitable for both automatic wiring (ALF and ADS) and manual wiring]
|
| Wire strip length |
8.0-9.0 mm
|
| Dual fixture master/slave |
Yes [ Master/Slave operation possible]
|
| Control input terminal cross section |
0.50-1.00 mm²
|
| Input terminal cross section |
0.50-1.00 mm²
|
| Output terminal cross section |
0.50-1.00 mm²
|
| Auto-insert (ALF/ADS) wire cross section |
0.75 mm²
|
| Cable capacity output wires to earth (max.) |
200 pF
|
| Rated ballast-lamp power |
28-35-49-54 W
|
| Rated lamp power on TL-D |
58 W
|
| System power on TL-D |
108.1 W
|
| Lamp power on TL-D |
101.1 W
|
| Power loss on TL-D |
7.1 W
|
| Rated lamp power on PL-L |
55 W
|
| System power on PL-L |
108.4 W
|
| Lamp power on PL-L |
101.6 W
|
| Power loss on PL-L |
6.8 W
|
| Rated lamp power on TL5 |
28/35/49/54 W
|
| System power on TL5 |
63.0/77.9/111.4 W
|
| Lamp power on TL5 |
58.9/73.6/107.2/113.4 W
|
| Power loss on TL5 |
4.1/4.3/4.2/6.3 W
|
| Rated lamp power on TL5 ECO |
25/32/45/50 W
|
| System power on TL5 ECO |
53.7/70.3/99.7/108.7 W
|
| Lamp Power on TL5 ECO |
50.8/66.5/95.6/102.7 W
|
| Rated lamp power on TL-D ECO |
51 W
|
| System power on TL-D ECO |
95.8 W
|
| Power loss on TL-D ECO |
6.0 W
|
| Lamp power on TL-D ECO |
89.8 W
|
| Power loss on TL5 ECO |
2.9/3.8/4.1/6.0 W
|
| T-ambient (max.) |
50 °C
|
| T-ambient (min.) |
-25 °C
|
| T storage (max.) |
80 °C
|
| T storage (min.) |
-40 °C
|
| T case lifetime (max.) |
75 °C
|
| T-Case maximum (max.) |
75 °C
|
| Stable lamp operation temperature |
15°C
|
| T-Ignition (max.) |
50 °C
|
| T-Ignition (min.) |
-25 °C
|
| Control interface |
TD
|
| Regulating level power |
1%-100%
|
| Control input protection |
Yes (Basic insulation)
|
| Housing |
L 359x30x21
|
| Battery voltage lamp ignition |
198-254 V
|
| Battery voltage lamp operation |
176-254
|
| Energy efficiency index |
A1 BAT
|
| IP classification |
IP 20 [ Ingress Protection 20]
|
| EMI 9 kHz ... 30 MHz |
EN55015
|
| EMI 30 MHz ... 1,000 MHz |
EN 55022 Class B
|
| Safety standard |
IEC 61347-2-3
|
| Performance standard |
IEC 60929
|
| Quality standard |
ISO 9000:2000
|
| Environmental standard |
ISO 14001
|
| Harmonic current emission standard |
IEC 61000-3-2
|
| EMC immunity standard |
IEC 61547
|
| Vibration standard |
IEC68-2-6 F c
|
| Bumps standard |
IEC 68-2-29 Eb
|
| Humidity standard |
EN 61347-2-3 clause 11
|
| Approval marks |
CE marking ENEC certificate VDE-EMV certificate |
| Temperature marking |
Yes
|
| Emergency standard |
IEC 60598-2-22
|
| Humming and noise level |
Inaudible
|
| Full product code |
871829166209900
|
| Order product name |
HF-Ri TD 2 28/35/49/54 TL5 E+ 195-240V
|
| EAN/UPC – product |
8718291662099
|
| Order code |
66209900
|
| Local order code |
HFRITD22854T5PL
|
| SAP numerator – quantity per pack |
1
|
| Numerator – packs per outer box |
12
|
| SAP material |
913700695866
|
| SAP net weight (piece) |
0.316 kg
|
Standard Delivery 2-5 Days Over FREE (*Excluding items over 600mm in length) Next Day Delivery Available - £12.50 (Order By 2pm For Monday-Friday)
We can also deliver into Europe and the rest of the world, but price is dependent on weight and dimensions. Price is variable and is given upon checkout. Often we will quote as close to the price as we can, however in some circumstances, with shipping outside of the UK, we will contact you and quote you a price once the order has been received.
For next day delivery (at an additional charge), your order must be placed by 2pm Monday to Friday. Next day delivery does not include weekend delivery, and as such all orders placed next day on a Friday will be delivered the following Monday, or if after 2pm will be delivered on Tuesday
If you order the wrong product, please inform us within 14 working days and we will advise you of the correct product and return procedures. Please note if this is the case, then responsibility and cost of returning this item is that of you the customer.
If the item you ordered is damaged please advise us within the first 48 hours of receiving and we will collect and replace free of charge.
As we sell cable by the metre, this often comes cut from a 100m reel. for this reason, cut cable is NON-RETURNABLE